High-Efficiency Furnace Leaking: What To Do

Furnace Leaking

606 Views

High-efficiency furnaces are prone to water leakage, but several possible reasons exist. If you have been experiencing a leaky furnace, it is vital to determine the cause so that you can take steps to correct it. In this blog post, we will explore some of the most common reasons for high-efficiency furnace leaking water so that you can identify the source of your problem and correct it.

Leaking From Condensate Drain Hose

If your furnace leaks water, it may be due to a problem with the condensate drain hose. The condensate drain hose is responsible for carrying away water produced when the furnace operates. If the hose is damaged or blocked, it can cause water to leak from the furnace. If you suspect that your furnace is leaking due to a problem with the condensate drain hose, you should check the hose for signs of damage or blockage. In addition, you should make sure that the hose is correctly connected to the furnace. Contact a qualified heating and cooling technician for assistance if you cannot fix the furnace leaking water problem.

Inducer Assembly Leaking

If you notice your furnace leaking water, it is most likely due to a problem with the inducer assembly. The inducer assembly is responsible for drawing air into the combustion chamber and is located near the bottom of the unit. Over time, the rubber gasket that seals the inducer assembly can degrade, allowing water to leak. If left unchecked, this can cause severe damage to your furnace. Fortunately, replacing the gasket is a relatively simple process that can be completed in a few minutes. However, if you are not comfortable working on your furnace, it is best to call a professional for assistance. You can keep your furnace running smoothly for years with some care and attention.

Leaking From Condensate Drain Line

One potential cause of water leaking from your furnace is a problem with the condensate drain line. This line is responsible for carrying away moisture that condenses on the heat exchanger. If the drain line becomes blocked or clogged, the water can back up and leak out of the furnace. However, if the line is genuinely blocked, you will need to clear or replace it entirely. In either case, it is best to call a qualified technician for assistance. Otherwise, you could end up causing further damage to your furnace.

Condensate Pump Leaking

First, check the pump for any signs of damage or leaks. If you notice a slow water drip around your furnace, the condensate pump is likely the cause. If you find a leak, you may be able to repair it with a sealant. You will need to replace the pump if it is damaged beyond repair. In either case, it is best to consult a qualified heating technician before proceeding. A small leak from a condensate pump may not seem like a big deal, but it can cause severe damage to your furnace over time. If left unchecked, a leaking condensate pump can lead to corrosion and other problems that can shorten the lifespan of your furnace.

High-efficiency furnaces are a great way to save energy and money, but only if they function correctly. Not only will this keep your home safe and comfortable, but it will also help protect your investment in this valuable piece of equipment. If your furnace leaks water, call a professional for repairs before the problem worsens.